Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBALLANTYNE HOTEL AND LODGE, THE POOL INDOOR
Address10000 BALLANTYNE COMMONS PKY
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/24/2018
Final Score @ Grade
24
General Comments2.6 HP on 1.5 HP pump, need to update our internal records to reflect this change which has been approved by Katie Wilson.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Daily written records missing some pool maintenance. All other aspects of records in compliance. Maintain daily records of pH, bromine (disinfectant residual), main drain checks, temperature, activities pertaining to pool maintenance and weekly TA and CA.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some scum and buildup on pool floors/walls. Algae buildup around top of coping in pool. Keep clean.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fencing with gaps greater than 4" at bottom. Keep less than 4". Constructed prior to 2010, so no permit action.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Planted tree within 5' of pool. Maintain 5' deck clearance. Operator moved tree. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck at time of inspection. Keep functional flow meter. Operator corrected to work properly.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Forced ventilation turned off in chemical room. Keep forced ventilation or cross vent. Operator turned on. Corrected.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms greater than 110 degrees F. Maintain hot water at 110 degrees F and below.