NameWINGATE BY WYNDHAM
Address2001 MT HARMONY CHURCH ROAD
 
City/State/ZIP
MATTHEWS NC 28104
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/10/2020
Final Score @ Grade
14
General CommentsPOOL IS CLOSED BY ORDER OF THE HEALTH DEPARTMENT. POOL PERMIT IS SUSPENDED UNTIL ALL SUSPENSION ITEMS ARE CORRECTED AND HEALTH DEPARTMENT CONDUCTS FOLLOW-UP VISIT. FACILITY WAS ALLOWED TO POST A POOL CLOSED SIGN RATHER THAN HAVE DEPARTMENT "CLOSED BY ORDER OF THE HEALTH DEPARTMENT" SIGN POSTED. SIGN MUST STAY POSTED AND POOL MUST REMAIN CLOSED UNTIL HEALTH DEPARTMENT LIFTS PERMIT SUSPENSION. FAILURE TO DO SO MAY RESULT IN LEGAL ACTION FROM THE HEALTH DEPARTMENT. POOL HAS MAIN DRAINS THAT WILL EXPIRE APRIL 2020. POOL HAS EQ COVERS THAT WILL EXPIRE DECEMBER 2021. COVERS MUST BE CHANGED OUT BEFORE THEY EXPIRE AND PROPER PAPERWORK (PDSC FORMS AND SUCH) MUST BE SUBMITTED TO THE DEPARTMENT FOR REVIEW AND APPROVAL. PUMP MOTOR WAS CHANGED OUT DECEMBER 7TH 2019. MECKLENBURG COUNTY CODE ENFORCEMENT MUST BE CONTACTED AND PROPER PERMITS AND INSPECTIONS MUST BE OBTAINED FOR THE PUMP MOTOR CHANGE. FAILURE TO HAVE WORK APPROVED BY CODE ENFORCEMENT WILL PREVENT POOL FROM OBTAINING OPERATIONAL PERMIT IN THE NEXT YEAR UNTIL THIS IS DONE.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH to be 8.0. Safe range for pH is 7.2-7.8. pH must be corrected to 7.2-7.8. Correct pH. PERMIT SUSPENDED
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed one day missed on current month of daily record. (2/9/2020) Disinfectant, pH, Temperature, and Main Drain condition must be checked every day the pool is open for swimming. Total Alkalinity must be checked at least one time a week. Cyanuric acid, if used, must be checked at least one time a week and cannot exceed 100ppm. CPO must visit the pool every day the pool is open.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed entrance door from lobby to self-close, but not properly self-latch. Entrance doors onto the deck must self-close and self-latch or be audible alarmed to alert when opened. Correct the door.