Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHUNTERSVILLE FAMILY FITNESS - LAP
Address11725 VERHOEFF DRIVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/8/2026
Final Score @ Grade
12
General CommentsMAIN DRAIN COVERS EXPIRE 12/11/2028 INTENT TO SUSPEND ISSUED FOR THE DOOR NOT SELF-CLOSING AND FOR THE DEPTH MARKERS BEING MORE THAN 25 FEET APART. DEADLINE IS 10/8/20206. FAILURE TO CORRECT THESE ISSUES BY THE DEADLINE WILL RESULT IN THE CLOSURE OF THE POOL UNTIL CORRECTIONS ARE MADE. Resurface of pool deck requires infield plan review application prior to work - 2025New pump to be installed - requires electrical IFPR approval and field verification for final approval - 2025Permit Restriction - Flow meters must remain operable on each system. Flow not to exceed 1330 gpm (SCH80) due to flow restriction of the filter. Turnover - Combined flow of 2617 gpm. Flow greater than 1531 gpm exceeds the main drains. Suction Hazard. FLOW OF PUMP A WAS 1150 GPM FLOW OF PUMP B WAS 1200 GPM.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(a) Depth of the water shall be marked at or above the water surface on the vertical wall of the pool and on the edge of the deck next to the swimming pool. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. .2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed 2 depth markers at the diving boards to be 25 foot 8 inches apart. A marker must be added to the deck and the pool wall such that the distance between the markers is less than 25ft.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door to the outside on the exterior wall with the bleachers is not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. Intent To Suspend Issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed some holes in the deck where the deck plugs were missing. These present trip hazards. Corrected during the inspection. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.