NameHUNTERSVILLE FAMILY FITNESS - LAP
Address11725 VERHOEFF DRIVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/10/2024
Final Score @ Grade
28
General CommentsInspection conducted with George Evermann and CPO Kristen Sminchak. Inspection led by inspector Casey Aitcheson. New 30 HP replacement pump for system A installed. Verified permit E4549092 passed electrical inspection on 1-19-2024. Cut sheet for new pump submitted. Also need updated PDSC form and In-Field Plan review applications for new pump. Failure to get this documentation to the Health Department and approved will result in the permit being suspended. Forms emailed to CPO Kristen Sminchak. Verified Pump A and Pump B at 1200 GPM after a backwash. Blue-White Flow meter accurate to within +/- 10% accuracy. May need to be replaced to one that is accurate to within +/- 5%. Intent to suspend issued 9) 17)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Replacement pump for pump system A installed. PDSC and In-Field Plan Review application not yet submitted for approval. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Will follow up with the facility to ensure compliance.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Numbering missing from one of the depth markers on the pool wall. .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladder handrails loose. .2521 Install ladders per manufacturer instructions. Some starting platforms accessible. .2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision. Some of the diving boards with non-slip tread wearing thin or starting to chip off. .2517(a)4 Diving equipment shall be slip-resistant.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door from hallway and one door to outside not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck anchors missing. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Corrected. One lane line reel stored too close to diving board. Insufficient deck clearance. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Phone number that 911 has does not match. Number does not call back to the facility. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected. Temporary phone placed by emergency phone until it is fixed.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water 120.5F. .2526(i) Water in restrooms shall not exceed 110 F.