Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHUNTERSVILLE FAMILY FITNESS - LAP
Address11725 VERHOEFF DRIVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/24/2024
Final Score @ Grade
18
General CommentsInspection conducted with George Eversmann. Pump A - 1000 GPM, Pump B - 900 GPM. Facility using rubber mats at ladders due to the concrete becoming too worn down to be non-slip when wet. Maintain rubber mats such that they do not create a trip hazard. Prior to resurfacing pool deck, submit in-field plan review application to ensure new deck meets Health Department requirements. Intent to suspend issued 8) 11) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Gutter cover missing or popping up in places. Repair gutter to eliminate gaps and keep flush. Install per mfg. instructions. .2518(k)(2) The overflow trough shall be cleanable and maintained to minimize accidental injury. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladder handrails loose. .2521 Install ladders per manufacturer instructions. 1 meter diving platform with wooden supports extending into the pool water. .2517 Diving equipment shall be designed for pool use and shall be installed in accordance with manufacturer’s recommendations and include a label with manufacturer’s name, address and equipment specifications. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No One body hook broke off of pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. .2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. - Corrected. Operator able to get body hook from outdoor pool which has not yet been permitted until a replacement is obtained.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door from hallway, back door, and door to office/locker rooms not self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water 129.2F. .2526(i) Water in restrooms shall not exceed 110 F.