Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHUNTERSVILLE FAMILY FITNESS - LAP
Address11725 VERHOEFF DRIVE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/13/2023
Final Score @ Grade
22
General CommentsInspection conducted with Aquatics Director Kristen Sminchak. Kristen is the new CPO for this pool. Updated CDP with CPO information. Flow meter for pump closest to heater reading 990 GPM. Permit condition for flow meter to be operational at all times at 900 GPM. Corrected to ~910 GPM. Facility changed main drains to what appear to be VGBA 2008 Aquastar 24xxx main drains. Will need to submit updated PDSC information to our office and receive approval by 12/18. Failure to do so will result in a suspension of the pool permit. Intent to suspend issued 5) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records kept in 3 locations. Not checking temperature or main drains daily. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Like for like change of main drains on 12/11/2023. PDSC paperwork not yet submitted for approval. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Will follow up with the facility to ensure compliance.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladder handrails loose. .2521 Install ladders per manufacturer instructions.
22 6 Premises: emergency telephone provided No No No Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter for one of the pumps stuck. .2518(g) Keep flow meter operational. - Facility has ordered new flow meter. - Intent to suspend item.