Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHAMPTON INN
Address530 E MARTIN LUTHER KING JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/25/2025
Final Score @ Grade
26
General CommentsPool is closed by order of the Health Department. Contact C. Elmore when the closure issues are corrected. The pool cannot reopen without a verification visit by the Health Department. Contact C. Elmore when the items are corrected to schedule the follow-up. 704-507-6814 This pool only requires one ring buoy and throw rope. You can have more than are required, but all that are in the pool area must meet the requirements and the rope length for this pool. Throw rope length is 24 feet for this pool. Observed the flow meter to be sticking. Ensure proper operation of the flow meter. Observed weir to be installed backwards in the skimmer, the float foam portion of the weir is supposed to face away from the pool. This should be corrected to ensure proper skimmer operation. Observed motor/pump assembly to have shifted off of the mount and it appears that it is resting on the floor of the pump room. Correct this so that the motor and pump assembly are not in contact with the wet floor. Ensure that a CPO attends the pool every day that the pool is open and that the logs are properly kept everyday the pool is open. Main drain covers and equalizer line covers at this pool will expire 10/18/2026.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine to be at 0.2 PPM. This is 20% of the required minimum for safe operation of the pool. Correct the chlorine. Chlorine for operating the pool must be added to the pool by way of the chlorination system. Do not hand feed or add disinfectant directly to the pool for operation. This can only be done for maintenance or shocking when the pool is closed.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. Observed no record in the log for 9/19/2025, 9/23/2025, 9/24/205. As there are no records for the last 2 days it is unclear when the chlorine in the pool dropped below safe levels. Keep proper records with the proper recording of who takes the readings. Ensure a CPO is available every day to attend the pool. No Permit Action taken for this violation at this time.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed floor return cover to have been secured with screws that have corroded. They are now protruding from the faceplate to the floor return cover where they present a hazard where a bather could injury their foot from coming into contact with the rusty screws. Correct this hazard and always use non-corrosive hardware for applications inside the pool.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed outer entry door and access door next to the emergency phone not properly self-closing and self-latching. Correct the doors.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Phone not operable. Phone shall connect to 911. 911 shall have correct address and phone number and phone shall audibly ring back.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed water in the pump room to the extent that it could impact the pump and motor. Correct the wet conditions of the pump room.