NameHAMPTON INN
Address530 E MARTIN LUTHER KING JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/7/2021
Final Score @ Grade
20
General Comments6 - Drain covers and equalizer lines expire on 10/20/2021. Due for replacement prior to expiration date. Once replaced, submit updated PDSC form for approval. Immediate Suspension issued for emergency phone. Phone not operable. Once corrected, contact Katie Rudisill at 704-309-5494 to schedule a return inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
22 6 Premises: emergency telephone provided No No No Phone not operable. Phone shall connect to 911. 911 shall have correct address and phone number and phone shall audibly ring back. Immediate Suspension issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Original construction. If replaced, install flow meter per NSF approval.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at pump. Could not verify location; however appears to be a gasket/seal. Repair leak. Flow meter stuck. Keep operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak at pump. Keep dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >120 F. Maintain at 110 or below.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Check valve for fill line ASSE1015. Original construction. If ever replaced, replace per .2512 or with ASSE 1013 check valve.