Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHAMPTON INN
Address530 E MARTIN LUTHER KING JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/24/2020
Final Score @ Grade
14
General CommentsNote - Main drains and equalizer line covers expire in October 2021. New covers shall be installed along with PDSC form once work has been completed. If not received prior to expiration, the permit will be suspended. Intent to Suspend issued for leak in pump room (could not verify if leak was from pool or spa filtration pump) and damage to deck drain. Lynn Sizemore present during the inspection. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Floor wet due to drainage back-up when spa jets are run. Issued ITS on spa permit. .2522(f) Deck shall be sloped to drain. Deck drain damaged near spa. Repair damaged deck drain. Intent to Suspend issued. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Appears that both pool and spa pumps may be leaking - definite leak on one. Per operator a new motor has been ordered. Ensure electrical permit has been pulled and finaled prior to re-opening the pool/spa once work has been completed. Intent to Suspend issued. Repair leaks.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water on pump room floor due to leak. Keep dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water in restrooms and at pool shower at 121 F. Maintain at 110 F or below.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Check valve for fill line ASSE1015. If ever replaced, replace with ASSE1013. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.