5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Test kit with black build-up in colander for cyanuric acid. Replace test kit. Intent to suspend issued.
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some chipping paint on pool floor and pool steps. No hazard to public.2537(14) Keep pool surface and pool floor free of debris.
Blue paint used on pool floor. Provide Light Reflectance Value testing for paint used within 30 days. Pool paint shall reflect at least 50% of light. .2514(c) Pool finish shall be white or light colored. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed planter at 4.5 ft from pool. Corrected during inspection.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times.
Deck drain painted over in some locations. Pool shall drain to deck drains. Drains do not drain properly due to paint. .2522. Intent to Suspend issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet due to leaking hose bib. .2533(d) Pump room floor shall be kept dry and free of standing water.
Pool equipment not easily accessible. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Water in restrooms greater than 110 F. .2626(i) Water in restrooms shall not exceed 110 F. |