Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTAYBRIDGE SUITES-BALLANTYNE
Address15735 BRIXHAM HILL AVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/8/2025
Final Score @ Grade
16
General Comments30 Day Intent to Suspend for providing CPO and flow meter operational. Permit expires 5/31/2025. Failure to correct and contact Marie Daley at 704-507-6806 PRIOR to this date will result in no active permit to operate. “W” status Inspection with DonAndre Nembhard

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Unable to locate CPO certificate at time of inspection. *permit item .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Entry railing loose at time of inspection. .2521 Install ladders per manufacturer instructions.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter installed prior to pool heater. Not installed per mfg. instructions. Install flow meter per mfg. instructions on return line. No flow restriction on pump. Does not require repair. If replaced in future, ensure installed per mfg. instructions. Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak. No clearance around equipment. Pool built 2001. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in women’s restroom over 110 F at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib in restrooms. Provide hose bib so that restrooms can be reached with a 50 ft. hose.