Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTAYBRIDGE SUITES-BALLANTYNE
Address15735 BRIXHAM HILL AVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/12/2023
Final Score @ Grade
18
General CommentsImmediate suspension issued for water quality. Pool must remain closed with signage posted until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Main drain covers expire Feb 2024. Replace and submit PDSC to pdsc@mecknc.gov for approval prior to expiration to avoid permit action. “E” status

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Immediate Suspension item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 2 of 2 weirs missing at time of inspection. .2518(k) Replace missing weirs. Corrected.
22 6 Premises: emergency telephone provided No No No Dialing instructions faded on phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator added and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3' clearance around piping. Some water on floor in equipment room. Floor not sloped to drain. Pool built 2001. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be sloped to drain. .2533(d) Pump room floor shall be kept dry and free of standing water.