Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Old fill spout cut off and small metal plug protruding more than 1/2" from deck at 5 FT side. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*30 Day Intent to Suspend (ITS) item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some standing water on pump room floor. No 3' clearance around piping. Floor not sloped to drain. Pool built 2001. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(d) Provide drain in pump room floor. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in women's restroom over 110 degrees F at time of inspection.
.2526(i) Water in restrooms shall not exceed 110 F. |