8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One of 2 weirs missing at time of inspection. .2518(k) Replace missing weirs. Operator has weir on order to be delivered on day of inspection with email verification provided. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some standing water on pump room floor. No 3' clearance around piping. Floor not sloped to drain. Pool built 2001. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(d) Provide drain in pump room floor. |