8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 1 weir missing. .2518(k) Replace missing weirs. Operator replaced weir and emptied baskets. Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs and pool furniture within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No 3' clear walking space around piping. Vats of chemicals in pump room. Dry bags of chemicals on floor in chemical room.Some dry chemicals stored over large liquid vats in chemical room. Pool built 2000. Pump room unlocked at time of inspection. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Women's restroom soap dispenser broken off wall, not able to use at time of inspection. Extra soap provided.
.2526(m) Keep restrooms and fixtures clean and in good repair. |