16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gates with push bar, less than 54" in height have openings in mesh greater than 1/2". One side gate at time of visit. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
.2537(b) All gates and doors shall be self-closing, self-latching. Operator placed plastic piece on fence to cover openings and adjusted gate to self-close, self-latch. Corrected.
Fencing with horizontals less than 45" in some areas. Pool built 2000.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No 3' clear walking space around piping. Vats of chemicals in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No paper towels in men’s restroom. Provide for hand drying.
Could not tell if mirrors are shatterproof. .2526(k) Provide shatterproof mirrors or backing. |