NameBEXLEY CROSSING AT PROVIDENCE
Address11215 CLUB CREEK LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/31/2022
Final Score @ Grade
8
General CommentsLifted suspension for expired Intent to Suspend items (spare pump basket and records) and conducted pre-permit inspection. Issued local permit sticker. No Night Swimming. Electrical permit (E4203387) issued for motor change out, finalized 5/2022. CPO updated to Mathew Timeus, certification number NC18221626. Note: Two pumps, tied to one system, one placard does not match impeller verification. ‘ Main drains expire October 2023. Replace and submit updated PDSC for approval prior to expiration to avoid permit action. Skimmer equalizer covers expires March 2024

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates with push bar, less than 54" in height have openings in mesh greater than 1/2". One side gate at time of visit. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. .2537(b) All gates and doors shall be self-closing, self-latching. Operator placed plastic piece on fence to cover openings and adjusted gate to self-close, self-latch. Corrected. Fencing with horizontals less than 45" in some areas. Pool built 2000. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3' clear walking space around piping. Vats of chemicals in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels in men’s restroom. Provide for hand drying. Could not tell if mirrors are shatterproof. .2526(k) Provide shatterproof mirrors or backing.