Premises Information

Return to Inspections
NameBEXLEY CROSSING AT PROVIDENCE
Address11215 CLUB CREEK LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/2/2020
Final Score @ Grade
20
General CommentsIntent to Suspend (ITS) for weirs and gates self-closing, self-latching. PDSC form on file indicates Sta-rite P4E6FL 1.5 HP. Both motors have been replaced with 2 HP motors. One pump missing tag and other indicates P4E6G-189L (a 2HP pump). Documentation from 4/16/19 has impellar verification, that does not match tag. If pump has been changed submit updated PDSC. Ensure proper electrical permits have been pulled. No signature due to COVID-19. Inspection with: Shawn Stacey Report to: shawnstacey42@gmail.com Restrooms were remodeled and mirrors have not been documented as shatterproof. Provide shatterproof mirrors in restrooms for pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir missing at time of inspection. .2518(k) Replace missing weirs. *30 Day ITS item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose and missing rubber stoppers at time of inspection. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed buoy rope cut by landscaping, not in good repair and 57'. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator replaced with new 50' rope. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pedestrian gate (with sidewalk) not self-closing, self-latching at time of inspection and open. This gate remains locked, but classifies as a pedestrian gate, rather than service gate. .2537(b) All gates and doors shall be self-closing, self-latching. *30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Not 3' clear walking space around piping. Dry chemicals stored on floor and in pump room. No backflow prevention on hose bib. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. *Spare pump basket from old spa can be used. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower off at time of inspection. .2526(h) Shower(s) shall be provided.