Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBEXLEY CROSSING AT PROVIDENCE
Address11215 CLUB CREEK LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/24/2018
Final Score @ Grade
14
General CommentsPermit issued. No Night Swimming. Items from suspension have been corrected (contrasting color bands). **Note: Plaster color is darker than required (less than 50% black, between value of 2 and 3 on grey scale and not in compliance). .2514c. Per Tim Dutcher, if any work is done pool must meet compliance with rules. .2514c, code requirement for construction.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder missing rubber stop. Keep in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Maintenance gate not self-closing at time of inspection. Ensure gates self-close, self-latch. Operator tightened and corrected to self-close, self-latch. Gate entrance on left side of clubhouse had magnet latch installed less than 30", protruding out greater than 1", creating foothold. Eliminate handhold/foothold on gate puilt prior to 2010 (30"-45"). Operator installed slanted metal piece to eliminate horizontal foothold. Magnet latch has battery backup. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Provide spare pump basket. Spare pump basket from spa pump, same type, from filled in spa can be used. Corrected.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Provide soap in men's restroom. Hot water over 110 degrees F in restrooms. Maintain hot water at 110 degrees F and below.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Provide vacuum breaker for hose bibb on pool deck.