Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameQUALITY SUITES
Address9840 PINEVILLE-MATTHEWS ROAD
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/7/2023
Final Score @ Grade
36
General CommentsImmediate Suspension (IS) issued for water quality and temperature. Ensure feeder is operating correctly, do NOT hand feed chlorine and contact Marie Daley at 704-507-6806 when in compliance. Pool MUST REMAIN CLOSED with signage posted until suspension is lifted by Health Dept. “E” Immediate Suspension item Other permit items to verify at return visit: records, CPO, doors self-closing, self-latching or alarmed, feeder turns off with pump

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm. *Immediate Suspension item
3 6 Water quality: pool water pH No No No PH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate Suspension item.
4 6 Water quality: water temperature of heated pool No No No Temperature of pool 99.5 F at time of inspection. .2535(12) Maintain pool temperature at 90 F or below. *Immediate Suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No active certified pool operator (CPO) for establishment at time of inspection. Per a manger, there is a CPO, but is not on property daily. CPO should be responsible for training staff to ensure pool is maintained daily, including weekends and days CPO is absent. Records not being kept at time of inspection. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator..2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records *30 Day Intent to Suspend (ITS) item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Unable to check back door at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *Will check on return visit. *Permit item
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Feeder not working properly at time of inspection. Also unable to verify feeder shuts off with pump. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. .2535 Automatic acid and chlorine feeders shall be automatically prevented from operating when the circulation pump is not in operation. *30 Day ITS item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No clearance around piping and equipment in pump room. Chemicals stored and in use in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms over 110 degrees F at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No floor drains in restrooms. Pool built 2000. .2526(c) Floor drains shall be provided in restrooms.