Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameQUALITY SUITES
Address9840 PINEVILLE-MATTHEWS ROAD
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/8/2022
Final Score @ Grade
20
General CommentsIntent to Suspend (ITS) for records, CPO certification, flow meter. Unable to verify door onto pool deck from outside at time of inspection. Will check buoy and door on 11/15. Note: Pump had wire that was not grounded. Operator stated this is not needed for pool. When following other grounded electrical casing, from pump motor, it lead to switch. Unable to verify grounding. Referring to Code Enforcement for further enforcement. Inspection with Hannah Howard and Rudy Ze La Torre

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No certified pool operator (CPO) for establishment at time of inspection. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. No records available at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records *30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Beckets around buoy have detached, but are still in working order. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. *Allowing 7 days for replacement due to lack of severity. Will verify item on Tues 11/15. Failure to correct will result in permit action.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational. *ITS item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No clearance around piping and equipment in pump room. Chemicals stored and in use in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms over 110 degrees F at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No floor drains in restrooms. Pool built 2000. .2526(c) Floor drains shall be provided in restrooms.