Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameQUALITY SUITES
Address9840 PINEVILLE-MATTHEWS ROAD
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/19/2019
Final Score @ Grade
16
General CommentsITS for records, flow meter and inlet fitting. Unable to verify chlorinator, will verify on return visit. New feeder system installed, **Main drains (SDX Retro) and skimmer equalizer cover (Aquastar 6 HP) expires May 2020. Replace and update PDSC form for approval prior to expiration to avoid permit action.** 22) When emergency phone was tested, emergency operator could not hear first statement. Emergency operator repeated self and phone connected. Recommended replacing phone for connection immediately.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly total alkalinity, has cyanuric acid records (but do not think pool is using stablizier). Daily reading missing for day before inspection (11/19). .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. **ITS item
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Inlet fitting missing ring cover. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. **ITS item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not working at time of inspection. .2518(g) Keep flow meter operational. **ITS item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No New feeder equipment installed in pump room. No clearance around system. Chemicals stored in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Pool built 2000
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms above 110 degrees F. .2526(i) Water in restrooms shall not exceed 110 F.