21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Pool wall light inoperable. ** Replace/ repair. (Pool enclosure has additional lights.) |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water ~123F @ shower within pool enclosure. Hot water ~130F @ lavatories in hall restrooms.
** Maximum temperature allowed is 110F.
* Maximum temperature allowed is 110F. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
- Hose bib on pool deck does not have backflow prevention. ** Install vacuum breaker.
- Owner reports that water is added to the pool via hose bib on pool deck. ** Pool was designed with fill spout/ fill spout has been removed at deck level. |