5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Test kit with expired reagents. Replace test kit. Intent to Suspend issued. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some algae on pool floor. Continue to brush and keep clean. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. One ladder with distance from wall to edge of rung at >6". Both ladders missing end caps. Provide end caps. One ladder missing slip resistant tread. Operator stated he had tread onsite and would replace. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Grab rope on ring buoy starting to degrade. Replaced during the inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
>1/2" between post and gate on either side of push bar on one gate and >1/2" between post and gate on one gate. Maintain at 1/2" or less between post and gate. Intent to Suspend issued.
Gates with meshing with >1/2" openings. Original construction. Recommend replacing mesh to 1/2" or less within 18" of push bar. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No spare pump basket for new pump. Provide spare pump basket. Intent to Suspend issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored on floor in chemical storage room. Room not clearly accessible. Chemical drums stored in pump room. Recommend moving to chemical storage room so equipment can be clearly accessed. No room to walk in pump room. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bib in pump room without backflow prevention device. Provide backflow prevention device. |