5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No main drain checks. Spotty total alkalinity and cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
Cyanuric acid consistently 100ppm in log book. Tested today at well over 100ppm. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Intent to suspend item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy damaged. Throw rope heavily knotted. .2530(a) Provide USCG approved ring buoy with attached 24 foot throw rope at least 1/4 inch in diameter. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door to fitness room not self-closing and self-latching..2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some piping not labeled. No labeling on piping outside of the pump room. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash not discharged through an air gap. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms 129.3F. .2526(i) Water in restrooms shall not exceed 110 F.
Restroom stalls recently replaced. Both stalls in men’s restroom and one stall in women’s restroom do not have toilet paper dispensers. .2526(l) Provide toilet paper and dispensers in restrooms. |