Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOUNTRY SUITES LAKE NORMAN
Address16617 STATESVILLE RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/5/2024
Final Score @ Grade
30
General CommentsInspection conducted with Managers Bobby Prestwood, Mantham Kelaiya, Komal Kelaiya. Conducted pre-permit inspection. Verified electrical permit E4642865 passed inspection 6-6-2024. PDSC form submitted has been disapproved. Does not match what was installed. Worked with facility to submit updated and corrected PDSC form. New Permit Condition: Flow meter must remain operable. Flow required at 48 GPM to 74 GPM to meet turnover and flow restriction of the filter. - CPO not present to do backwash. Observed at 79 GPM, Which is within the accuracy range of the flow meter. Verified In-Field Plan review information New Pentair Whisperflo 015583, 1.1 HP Pump. New Blue-White flow meter. MD, Skimmer, Return lines 2” piping. New TR100 filter. 4x returns, 2x skimmers. Pre-permit inspection did not pass 5) 16) 24) Re-inspection scheduled for 1:00 PM on 8-8-2024. Prior to inspection, will need to pay $100 re-inspection fee by calling our office (980) 314-1620 and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Most reagents expired. Test kit heavily discolored. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Pre-permit item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC form submitted does not match what was installed. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. .2518(k) Replace missing weirs. Operator installed one of the weirs. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to fitness room not self-closing and self-latching..2537(b) All gates and doors shall be self-closing, self-latching. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pool recently replastered. Eyeball fitting installed on vacuum line. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Pre-permit item. Spare pump basket not observed for new pump. .2518(e) Provide a spare basket for pump. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan was removed from the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash not discharged through an air gap. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restroom 129.5F. .2526(i) Water in restrooms shall not exceed 110 F.