2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Cl 0.1ppm. .2535(4) Maintain chlorine at least 1.0 ppm. Corrected to 2 ppm. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records since January 14th. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator arrived during inspection to check and correct chemicals. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool tiles dirty. Clean regularly. Paint chipping from pool floor. Repaint as needed. .2537(14) Maintain pool walls and floor in good condition. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers off the in pump room. Water about 3 inches low. .2518(k) Water level shall be maintained to assure skimmers are operable. Corrected by operator, added additional water. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs too close to pool edge. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in the pump room next to pool piping. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Pump room door doesn't close and lock. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Pump room floor wet. Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some of the piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash not discharged through an air gap. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms > 110F. .2526(i) Water in restrooms shall not exceed 110 F. |