Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOUNTRY SUITES LAKE NORMAN
Address16617 STATESVILLE RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/5/2020
Final Score @ Grade
32
General CommentsInspection conducted with Piero Cominges. Due to COVID-19 precautions, inspection was not signed by the operator. Emergency phone rings back to the front desk. Ensure that front desk is staffed at all times or reroute emergency phone to call back to the emergency phone on the pool deck. Pool very cloudy, difficult to see the main drains. Ensure that pool is checked by hotel staff prior to opening the pool to guests every day. Posted permit expired in 2016. Go to Meckpools.Charmeck.org to print current permit and post in the pool area. Recommend installing a flow meter on the chlorinator so that the operator can determine how much chlorinated water is being added to the pool. Immediate suspension issued 2) Contact Will Harrison (704-507-6824) when issues corrected and ready for a reinspection. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0.3 ppm. Operator changed out chlorinator and after 30 minutes corrected to 0.5 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Pool using stabilized chlorine, no Cyanuric Acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. Chlorine checks consistently 3 - 5 ppm. Tested today at 0.3ppm. Ensure that test kit is accurate, samples taken away from returns, etc.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Paint on pool floor chipping off. Much worse than last inspection. Maintain pool walls and floor in good condition.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing one of two weirs. .2518(k) Replace missing weirs. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. Flow meter installed close to two elbows. .2518(g) Install flow meter on return line per manufacturer instructions.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals and non-chemical items all stacked on top of each other. Chemical storage room very cluttered. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Pump room door does not fully close, not able to stay locked. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Piping for heater not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.