| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.2. Maintain between 7.2 and 7.8. PH corrected to 7.3, operator will keep pool closed for one full turnover of the pool. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent records. Last record was from February? 5th. Spotty Cyanuric Acid records and no daily maintenance activities recorded
recently.
Check daily Cl, pH, Main Drains, Temperature, and Pool Maintenance Activities. Check at least weekly Total Alkalinity and Cyanuric
Acid. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Pool floor and walls chipping. Maintain pool floor and walls in good condition. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back doors not self-latching. This is a recurring issue. Ensure that doors to the pool area are self-closing and self-latching. - Intent to
suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Tile on ramp broken, exposing sharp edge. Maintain floor slip resistant and in good condition with no trip or cut hazards. - Intent to
suspend item. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lights off in the pool and spa area. Underwater lights also off. Ensure proper lighting in pool and spa area and that all parts of the
pool and spa are visible. Corrected, able to turn on lights for the room. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pool chemicals stored in the pump room. Store all chemicals in the chemical storage room.
Bag of sodium bicarb stored on the ground in the pump room. Store off the ground or in a bucket.
Provide either forced air or cross ventilation for chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Provide air gap for backwash. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water > 110F. Maintain at 110F or less. |