5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records very spotty. Check daily Cl, pH, main drains, pool maintenance activities and temperature. Check at least weekly Total Alkalinity and Cyanuric Acid. Maintain Cyanuric Acid at no more than 100ppm. - Intent to suspend item. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Some inlet fittings missing. Provide directional eyeball fittings. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Doors are not self-latching. Provide doors that are self-closing and self-latching. - Intent to suspend item. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lights off when arrived, operator able to get room lights and underwater light in shallow end on. Pool open for night swimming. Provide sufficient lighting to see pool bottom and all parts of pool deck when pool is open. - Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Store in chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Provide air gap for backwash. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water > 110F. Maintain at 110F or less. |