Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOUNTRY SUITES LAKE NORMAN
Address16617 STATESVILLE RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/25/2017
Final Score @ Grade
32
General CommentsPermit posted is from 2015. Go to Meckpools.charmeck.org to print current pool permit and post a copy in the pool area. 15) Wing nuts on body hook on the inside of the hook, potenially injuring someone during rescue. Recommend turning screws around such that wing nuts are on outside of hook. Intent to suspend issued. 5) 8) 17)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid at 100ppm. This is the maximum allowed. Pool using stabilized chlorine. Will need to reduce cyanuric acid levels in the pool to maintain below 100ppm. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing, another weir stuck. Install functional weirs. - Intent to suspend item. Skimmer lids are the wrong type. One stuck and recessed, creating a trip hazard. Replace with the correct covers for the pool skimmers. - Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing one inlet fitting. Provide directional inlet fittings.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged. Replace with US Coast Guard approved ring buoy attached to a 24 foot throw rope. - Corrected by operator.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Gaps in deck drains creating a trip hazard. Ensure no gaps or opeings > 1/2" in deck. - Intent to suspend item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Underwater light off. Provide underwater lighting when spa is open. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in chemical storage room tied to the light switch. Ensure that fan runs continuously and is not tied to the light switch.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water > 110F. Maintain at 110F or less.