3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0. Maintain between 7.2 and 7.8. Corrected to 7.2. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Eyeball fitting on vacuum line, vacuum line on. Line shall be plugged when not in use. Corrected. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Walls and floors with chipping plaster. Maintain in good condition. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers off in pump room. Skimmers shall be on to ensure proper circulation. Corrected. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap on backwash pit. Provide air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restroom > 110°F. Maintain at 110°F or less. |