NameCHARLOTTE HILTON AIRPORT HOTEL
Address2800 COLISEUM CENTRE DR
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/27/2017
Final Score @ Grade
24
General CommentsIMMEDIATE SUSPENSION ISSUED for #1 & #2. Pool cannot be re-opened without written approval from the Mecklenburg County Health Dept. Contact L. Boyes @ 704-507-6806.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No Pool cloudy. Main drain covers (& bottom of pool) difficult to see. ** Maintain clarity of water so that main drain covers are clearly visible from pool deck at all times. IMMEDIATE SUSPENSION
2 6 Water quality: disinfectant residual provided by No No No Observed Bromine level at .6ppm. ** Maintain Bromine level at a minimum of 2.0ppm. IMMEDIATE SUSPENSION
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir will not float & therefore is not functioning as designed. ** Replace weir.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Two of the (double) doors not self-latching properly. ** Repair.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No - No natural cross draft ventilation or forced air ventilation in equipment room. ** Provide. - Floor wet under circulation system- unable to determine source of water. ** If leak found, repair/ resolve.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No - Hot water at least 124F @ shower & @ lavatories in restrooms. ** Maximum temperature allowed is 110F. - No soap at lavatory in men's restroom. ** Provide soap.