5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Only one total alkalinity reading recorded thus far this month. ** Check & record total alkalinity at least 1 time per week. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
VGB information from 2015 PDSC form is no longer up to date. One equalizer line cover has been replaced.
** Submit new PDSC form to K. Wilson (Meck. Co. Health Dept.). Form must be approved.
Immediate Suspension issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Both weirs missing. ** Installed while EHS on-site. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light inoperable in chemical room. ** Resolve. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water at least 127F @ shower (inside pool enclosure) & @ lavatories.
** Maximum temperature allowed is 110F. |