Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity.
Some records missing from the end of July. All records missing from August. Operator found missing records in office. No permit action. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment should be conspicuously and conveniently located.
Body hook not easily accessible or visible. Operator corrected. No permit action.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
Ring buoy rope less than approved 35ft due to knot. Operator untied and corrected. No permit action. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operable at time of inspection. Operator corrected and new reading shows 100gpm. Ensure flow on pump is at least 120 gpm for turnover. No permit action.
.2518(g) Keep flow meter operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room in above ground vault, difficult to access. Built in 1999.
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft.
Not able to easily access pool equipment.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Pump room and chemical storage room vaults unlocked.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Chemical storage in a small plastic shed.
.2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft.
No forced ventilation in above ground vault.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |