Water quality: pool water pH |
No |
No
|
No |
Observed pH at 6.8. Adjusted to 7.3 onsite. CDI
.2535(1) Maintain pH at 7.2 to 7.8. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Emergency phone can not receive calls. Immediate suspension item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operable at time of inspection. Flow restriction on pump must be at least 120 gpm for permit restriction. .2518(g) Keep flow meter operational. Flow meter fixed and operational during inspection. CDI |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room in above ground vault, difficult to access. Built in 1999. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft.
Leak at filter, filter partially underwater. .2533(d) Pump room floor shall be kept dry and free of standing water.
Not able to easily access pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Pump room and chemical storage room vaults unlocked. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. |