Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSAGEWOOD, THE
Address14325 PLANTATION PARK BLVD
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/4/2021
Final Score @ Grade
24
General CommentsITS for records and fence 48" in height. "W" Status. General Comment: Pool signage with "Adults should not swim alone." and "Children should not use the swimming pool without adult supervision" 1" in height, starting to peel. Recommended replacing before illegible. Ensure all signage rules and letting height/exact wording are in compliance for sign. Send to Marie Daley at marie.daley@mecknc.gov if there are questions for approval Another sign still meets compliance. The VFD remains at 58 HZ and flow meter reading about 190 gpm at time of inspection. Pump meeting minimum turnover and no apparent suction hazard. Permit restriction outlines 60 HZ. Advised adjusting, but did not take permit action. Main drains expire Feb 2022. Replace and submit updated PDSC form prior to expiration to avoid permit action CPO updated to Antoine Caldwell Unable to verify lighting. No Night Swimming unless verification is sent to Marie Daley at 704-507-6806 Inspection with Julius Dennis No signature due to COVID

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drain check not on records at time of inspection. Records missing daily records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added column for main drain check and corrected. *Issued 30 Day Intent to Suspend (ITS) Will return to verify daily records
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Bottom tread missing slip resistant strip on ladder. .2521(b) Ladders shall have slip-resistant tread.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope detached from buoy at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator tied rope onto buoy, secured and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Brick wall less than 30"in height creating horizontal by restroom door. Brick wall and outlet box by garage less than 30" in height. One gate swinging in toward pool due to stairs. Pool built 99. .2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. .2528(b) Maintain between 30" or greater between bottom horizontal and next horizontal on fence and/or gate (pre-May 2010). Landscaping shortening height of fence by grill area less than 48. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. *ITS item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Equipment and chemicals stored under large plastic pieces outside. No walking space/clearance. Water under pump. Chemicals stored in garage with no ventilation. Pool built '99. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft..2533(d) Pump room floor shall be kept dry and free of standing water. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Dry chemicals in same area as liquid vats of acid and chlorine. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Operator moved dry chemicals. Corrected.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow prevention device on spigot at shower. Provide backflow prevention device