Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSAGEWOOD, THE
Address14325 PLANTATION PARK BLVD
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/12/2020
Final Score @ Grade
16
General Comments30 Day Intent to Suspend (ITS) for doors onto pool deck self-closing, self-latching or audible alarm. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. CPO updated to Bechord Walcott, expires 2023 No signature due to COVID-19 Report to: Plantation Park Maintenance ; Plantation Park Assistant Manager

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drain check not on records at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added column for main drain check and corrected.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Overflow grate cracked on pool wall. Keep in good repair.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Bottom tread missing slip resistant strip on ladder. .2521(b) Ladders shall have slip-resistant tread.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door onto pool deck by restrooms not self-latching or alarmed at time of inspection.* Door also propped open for restroom entry at time of inspection. Brick wall less than 30"in height creating horizontal. One gate swinging in toward pool due to stairs. Pool built 99. .2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool..2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. .2528(b) Maintain between 30" or greater between bottom horizontal and next horizontal on fence and/or gate (pre-May 2010). *ITS item-doors onto pool deck
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Equipment and chemicals stored under large plastic pieces outside. No walking space/clearance. Chemicals stored in garage with no ventilation. Pool built '99. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.