Premises Information

Return to Inspections
NameTHE SHARON AT SOUTHPARK
Address5100 SHARON RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/28/2023
Final Score @ Grade
26
General CommentsInspection conducted with C Stepanski. All permit items in compliance by end of inspection. Aquastar 1216 drain covers expire 11/20/2024. Replace covers and submit PDSE for approval prior to expiration. Inspection conducted by EHS Devon Moeller with EHS Hope McIntosh.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Missing few days of records. All other records in compliance. No permit action.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Loose ladder at far end of pool.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope at 47’. Corrected to 45’.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Door leading directly onto pool deck propped open. Door closed during inspection. Door leading to pool deck should not be propped open.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automatic feeder not shutting off with pump at time of inspection. .2535 Automatic feeders shall be automatically prevented from operating when the circulation pump is not in operation. Operator adjusted and corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pool built prior to 2004. No spare pump basket. Unable to purchase/find. No permit action taken due to age of pump and ability to find/lack of severity. 2518(e) Provide a spare basket for pump.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water over 110 degrees F in restroom at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F.