11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
No tread on ladders into pool.
.2521(b) Ladders shall have slip-resistant tread. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool exercise signs within 5' of pool at time of inspection.
.2522(b) Provide at least 5 ft of clear walking space around the pool at all times. Operator moved. Corrected. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automatic feeder not shutting off with pump at time of inspection.
.2535 Automatic feeders shall be automatically prevented from operating when the circulation pump is not in operation. Operator adjusted and corrected.
Advised monitoring to ensure switch does not stay engaged with no flow. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pool built in '98. No spare pump basket. Unable to purchase/find. No permit action taken due to age of
pump and ability to find..2518(e) Provide a spare basket for pump. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Vent does not appear to be working in chemical storage at time of inspection.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |