23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automatic feeder not shutting off with pump at time of inspection.
.2535 Automatic acid and chlorine feeder shall be automatically prevented from operating when the circulation pump is not in operation.
*Permit item. Intent to suspend issued. Must correct by 4/30/2021 or new permit will not be issued. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pool built in '98. No spare pump basket. Unable to purchase/find. No permit action taken due to age of
pump and ability to find..2518(e) Provide a spare basket for pump. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
3' clearance not provided around piping in pump room. Pool built prior to 2004.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built '98.
.2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Women's restroom observed with no soap.
.2526(j) Provide soap and soap dispenser, no glass, at each sink. |