11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Two ladders loose. Ensure secure.
End caps missing off one ladder. Provide end caps.
Bolts rusted on ladder closed to bar area. All bolts/screws in pool shall be stainless steel. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Screw not secure in light at deep end. Corrected during the inspection and replaced. Screw was too long.
Some algae on ladders. Pool had algae bloom in previous weeks. Continue to treat as needed. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door from kitchen area not self-closing, self-latching. Repair to self-close, self-latch. Intent to Suspend issued.
Repeated issue of audible alarm being disengaged/removed from door from room. Previous inspections have had door not self-latching or audible alarm disengaged. Given until 2023 operating season for permanent repair to door to make self-closing, self-latching. Audible alarm will not be permitted due to previous inspection issues. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture less than 4 ft. to pool edge. Moved during the inspection to at least 6 ft. clearance. Maintain 6 ft. clearance around the swimming pool in all locations.
Some caulking/grout coming out of pavers in some sections around pool. Continue to monitor and repair as needed.
Some dead roaches on pool deck and around bar area. Keep pool deck clean and free of vermin. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Dialing instructions faded off of emergency phone. Written in during the inspection.
Note - front desk did not pick up immediately when number dialed to verify phone ringing back. If phone number posted dials back to the front desk, the front staff must be there 24/7 and answer at all times. If becomes an issue, will require direct ring back to pool deck. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automated feeder not calibrated. Showing 0.4 ppm and 7.7 for pH. Actual readings were at least 3.0 ppm and 7.2. Calibrate automated feeder. Intent to Suspend issued.
Operator could not demonstrate that automated feeder detects flow. Feeder shall detect flow and turn off when no power to pump. Operator shall demonstrate. Intent to Suspend issued.
No flow meter on stick feeder chlorinator. If ever replaced, provide flow meter per NSF requirement. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib/floor drains in restrooms. Original construction. Provide hose bib with backflow prevention and floor drains. |