NameOMNI CHARLOTTE HOTEL
Address132 E TRADE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/24/2019
Final Score @ Grade
22
General CommentsRing buoy blocked by umbrella. Keep accessible. Umbrella moved during inspection. State approval - glass service bottles are allowed behind the bar at the pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid recorded at 120 ppm. Could not verify at time of inspection due to low reagents. Maintain cyanuric acid at 100 ppm or less. Intent to Suspend issued. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. DPD-2 expires at end of July. Replace reagents as needed. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Two of three ladder handrails loose. Tighten and keep in good repair. .2521 Install ladders per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Screws in lights rusting. Replace with stainless steel. Intent to Suspend issued. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate at back entry to pool with latch less than 54" measured from outside of barrier. Doors on to pool deck off roof could not be verified. Intent to Suspend issued. .2528(a) Gate latches shall be 54" in height. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some pool chairs less than 6 ft. to pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor not sloped to drain. .2533(d) Pump room floor shall be sloped to drain. Bicarb stored on the pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib or floor drain in restrooms. Original restrooms. .2626(c) Floor drains shall be provided in restrooms. .2626(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.