Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSLEEP INN
Address6300 BANNER ELK DR.
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/3/2016
Final Score @ Grade
38
General CommentsVerified PDSC data matched what was installed. PDSC sheet states two equalizers lines, pool only has one. Permit will not be issued until we have updated form on file.SDX Retro cover installed on equalizer line. Permit will not be issued until A112 cover installed.Immediate suspension issued.3)22)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. Maintain between 7.2 and 7.8. - Immediate suspension item.
4 6 Water quality: water temperature of heated pool No No No Temperature 94.8F. Maintain at no more than 90F. NOTE: THIS IS A REPEAT ISSUE! CALIBRATE OR REPLACE THERMOMETER. Corrected to 85.5F.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records consistently read 80F for temperature, and consistently below 7.2 for pH with no corrective actions. THIS IS A REPEAT ISSUE! MAINTAIN PH BETWEEN 7.2 AND 7.8 AND CALIBRATE OR REPLACE THERMOMETER. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Plaster chipping on pool steps and pool floor. Repair.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Some inlet fittings missing. Install functional inlets.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table too close to pool. Maintain at least 5 feet clear walkway around pool. Corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone signage with missing city, state and zip code. Refers to a restaurant that no longer exists. Provide accurate signage with correct address and phone number. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in pump room tied to light switch. Fan shall run continuously. Inadequate ventilation in chemical storage room. Provide forced air ventilation.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water > 110F. Maintain at 110F or less.