Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSLEEP INN
Address6300 BANNER ELK DR.
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/9/2015
Final Score @ Grade
32
General Comments8) Equalizer line cover SDX Retro. This cover will need to be replaced with an approved A112 cover installed according to manufacturer's instructions before a permit will be issued this Spring.22) Dialing instructions do not list city, state and zip code. Also states it is located behind a restaurant that no longer exists. Provide correct address information.Verified PDSC form. Pool only has one skimmer and one equalizer line. Provide corrected PDSC form to the Health Deparmtment.Immediate suspension issued.3)4)17)Contact Will Harrison 704-507-6824 when issues have been corrected for a reinspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. Maintain between 7.2 and 7.8. - Immediate item.
4 6 Water quality: water temperature of heated pool No No No Temperature 96.6F. 90F is the maximum temperature. Maintain at 90F or less. - Immediate item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records show pool is consistently 1ppm Cl and 7.0 - 7.1 pH. Maintain pH closer to 7.4 and Cl of two or three ensure that chemistry is still good when pool is in use. Pool temperature in log was consistently 80F. Get new thermometer.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir not securely attached. Secure weir.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing some inlet fittings. Install functional inlets.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No One chair too close to pool edge. Maintain 5 feet clear walkway around pool. Corrected.One windows broken with exposed sharp edge. Replace window - Immediate item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan tied to light switch in pump room. Inadequate ventilation in chemical storage room. Provide continuous cross or forced air ventilation in chemical storage room and equipment room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water > 110F. Maintain at 110F or less.