| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No checks some Sunday's. Check daily Cl, pH, Temperature and drain covers. No total alkalinity checks. Check at least weekly. - Intent item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Equalizer line cover ripped out of the wall. Install A112 approved equalizer line cover. Fill out an updated PDSC form and submit to Health Department if new cover is installed. - Immediate item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer missing weir. Install functional weir. - Intent item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chair too close to handrail. Maintain at least 6 feet clear walkway around pool and 5 feet around ladders and handrail. Corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Was very difficult for 911 operator to hear me. Provide functional emergency phone. - Immediate item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Operator unable to fix. Provide functional flow meter. - Intent item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Inadequate ventilation. Provide either forced air or cross ventilation. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Provide toilet paper on a holder in restroom. |
|