NameSLEEP INN
Address6300 BANNER ELK DR.
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/22/2015
Final Score @ Grade
40
General Comments16 - General Comment: Back door propped open. Keep closed. Immediate Suspension issued for #2 and #3. Once corrected, contact Katie at 704-309-5494 to re-open pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No chlorine in pool. Maintain at least 1.0 ppm. Immediate Suspension issued.
3 6 Water quality: pool water pH No No No Pool pH at 8.4. Maintain at 7.2 to 7.8. Immediate Suspension issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some etching on pool floor and chipping plaster on steps. Keep in good repair.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not maintained on Sundays. Record main drain check, temp, chlorine and pH daily.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One return missing eyeball fitting. Replace.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope at 16 ft. Corrected to 14 ft.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Furniture 3 ft to pool. Maintain 5 ft clearance.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at pump. Repair.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light tied to fan in pump room and inadequate ventilation in chem storage room. Provide continuous forced or cross ventilation.