| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH at 6.8. Maintain at 7.2 to 7.8. Immediate Suspension issued. |
|
4
|
6
|
Water quality: water temperature of heated pool |
No |
No
|
No |
Observed water temp at 96.7 F. Maintain below 90 F. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed records not maintained on Sundays. No pool temp recorded. Main drain check, chlorine, pH and temp recorded daily. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed damaged plaster at steps. Keep in good repair. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed rope at 16 ft. Corrected to 14 ft. General Comment: Body hook pole at 10 1/2 ft. Required at 12 ft. Correct by 2/24/14. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed chairs 3 ft to pool. Maintain 5 ft clearance. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed cartridge filter with no extra filter. Provide extra filter. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed light and fan on same switch. Fan must run continuous when light turned out. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed water >110 F in restroom. Maintain at 110 F or below. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed cartridge drain pipe directly into drain. Provide air gap. |
|