Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSLEEP INN
Address6300 BANNER ELK DR.
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/16/2013
Final Score @ Grade
42
General CommentsImmediate Suspension issued for #2, #15 and #22. Once corrected, contatc Katie at 704-309-5494 to re-open pool. Note: Permit not posted. Post visible on deck. Meckpools.charmeck.orgNote: Extreme humidity present in pool room. Be cautious of mold issues.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed chlorine at 0.6 ppm. Provide at 1.0 ppm or greater. Immediate Suspension issued. Do not place granular in pool.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no log book. Maintain as required.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed skimmer without weir. Replace.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Observed wall depth markers missing from pool wall at deep end. Replace.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed one ladder rung missing off ladder. Replace.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed damaged ring buoy and rope at 11 ft. Replace buoy with USCG approved and provide 14 ft rope. Immediate Suspension issued.
22 6 Premises: emergency telephone provided No No No Observed phone automatic dial not connecting to 911. Immediate Suspension issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter stuck. Keep operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed pump room floor wet. Keep dry.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Clearly identify pipes with color codes or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed water in restrooms >115 F. Maintain at 110 F or below.