5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing maintenance/chemicals and incorrect readings. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Issued permit and will verify item on next inspection. Failure to comply will result in permit action. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy beckets detached. .2530(a) Provide USCG approved ring buoy. Operator corrected buoy. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not audibly ringing back at time of inspection.
.2530(f) Emergency phone shall remain operable. Operator replaced phone to audibly ring back. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some items within 3' of piping and equipment. Chemicals stored in pump room and on ground. Pool built '98.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms over 110 degrees F. .2526(i) Water in restrooms shall not exceed 110 F. No soap in men’s restroom.
.2526(j) Provide soap and soap dispenser, no glass, at each sink. |