NameCOURTYARD MARRIOTT/BALLANTYNE
Address15635 DON LOCHMAN LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/6/2020
Final Score @ Grade
20
General CommentsImmediate Suspension for emergency phone and pool pump/PDSC.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC information notes pool pump is PAC-FAB (Pentair Challenger) CFII-NI-1F 1 HP. Pool pump did not have identification at time of inspection and THP 1.65 (1.5 HP) motor on pump. Information does not match. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Pump curve for 1 1/2 HP is 120 gpm, drain covers rated 188 gpm. No apparent suction hazard, but must correctly identify pump. *Immediate Suspension item. Submit correct/updated information on PDSC form for approval. Contact Marie Daley at 704-507-6806 to lift suspension. Note: Electrical work requires proper permits and licensed electrician.
22 6 Premises: emergency telephone provided No No No Emergency phone not working at time of inspection. Dialed out, but could not hear on phone line. Operator replaced phone, but dial back number notes the number is inoperable when dialed. .2530(f) Emergency phone shall remain operable. *Immediate Suspension item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pump leaking at time of inspection. .2518(h) Provide approved pump in good repair. *30 Day ITS item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in pump room. Pool built '98. Water on floor in pump room from leak. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(d) Pump room floor shall be kept dry and free of standing water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water over 110 degree F in restrooms. .2526(i) Water in restrooms shall not exceed 110 F.